MicroNet Fibre to SAS/SATA II RAID Subsystem Manual de usuario Pagina 77

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 160
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 76
FIBRE-to-SAS/SATA RAID SUBSYSTEM
User Manual
77
7. Enable automatic rebuild if required. If enabled the RAID will be automatically
rebuild if it becomes degraded (i.e. a disk fails), provided a spare is available.
This option can either be Disabled, ASAP, or Background.
NOTE: The Auto Rebuild option is not available for RAID level 0.
NOTE: The performance of the system will slow down during a
rebuild.
IMPORTANT: When rebuilding a RAID you should not remove the
faulty disk until the rebuild is complete. If you must remove the
disk then the data should be backed up prior to removing the disk.
8. Select from the following sparing strategies:
If local sparing is selected, one of the selected disks will be assigned as the local
spare. If global sparing is selected and no global spare has been assigned (or the
current global spare is too small), a warning message will be displayed. A disk
that is assigned as a local spare can only be used by the RAID that it is assigned
to. Refer to Spare Drive Strategy Section on creating spare disks.