MicroNet Fibre to SAS/SATA II RAID Subsystem Manual de usuario Pagina 101

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 138
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 100
Fibre to SAS/SATA II RAID Subsystem
User Manual
101
5.6.3 Hardware Monitor
To view the RAID subsystem’s hardware information, click the Hardware Monitor link
from the Information menu. The Hardware Monitor Information screen appears.
NOTE: To disable auto refresh of GUI, tick the “Stop Auto Refresh”
option.
The Hardware Monitor Information provides information about controller, enclosure 1 and
enclosure 2, such as the temperature, fan speed, power supply status and voltage levels.
All items are also unchangeable. When the threshold values are surpassed, warning
messages will be indicated through the LCD, LED and alarm buzzer.
Item
Warning Condition
Controller Board Temperature
> 70 Celsius
HDD Temperature
> 65 Celsius
Fan Speed
< 1500 RPM
Power Supply +12V
< 10.5V or > 13.5V
Power Supply +5V
< 4.7V or > 5.4V
Power Supply +3.3V
< 3.0V or > 3.6V
DDR Supply Voltage +2.5V
< 2.25V or > 2.75V
CPU Core Voltage +1.3V
< 1.17V or > 1.43V
DDR Termination Power +1.25V
< 1.125V or > 1.375V
Vista de pagina 100
1 2 ... 96 97 98 99 100 101 102 103 104 105 106 ... 137 138

Comentarios a estos manuales

Sin comentarios