MicroNet Fibre to SAS/SATA II RAID Subsystem Manual de usuario Pagina 132

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 138
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 131
Fibre to SAS/SATA II RAID Subsystem
132
User Manual
3. In Raid Set Hierarchy, the Volume Set state will be shown as “Rebuilding”. Note
that Disk in Slot#1 is shown as “Failed”.
4. To power off the Disk in Slot#1 of Enclosure#1, select “Rescue Raid Set”
under RAID Set Functions. In the Enter The Keyword box, type “PowerOffDisk”,
press space bar, and then type “Enclosure#1 Slot#1”. The contents of “Enter
The Keyword” box will become “PowerOffDisk Enclosure#1 Slot#1”. Tick
“Confirm The Operation” and click “Submit”.
Vista de pagina 131

Comentarios a estos manuales

Sin comentarios