MicroNet Fibre to SAS/SATA II RAID Subsystem Manual de usuario Pagina 121

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 138
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 120
Fibre to SAS/SATA II RAID Subsystem
User Manual
121
4. In the text box provided, enter the command “HaltCtrl0”. Tick “Confirm The
Operation” and click “Submit” button.
NOTE: Use same command “HaltCtrl0” when testing Controller 2.
5. The Web GUI will show “Controller Will Be Halted In 6 Seconds”.
6. All access to Controller 1 will be switched to Controller 2. And all LEDs of
Controller 1 (the failed Controller) will be flashing.
NOTE: If Controller 2 Failure is being tested, all access to
Controller 2 will be switched to Controller 1.
7. Check if there is continuous access to the volumes.
Vista de pagina 120
1 2 ... 116 117 118 119 120 121 122 123 124 125 126 ... 137 138

Comentarios a estos manuales

Sin comentarios