MicroNet Fibre to SAS/SATA II RAID Subsystem Manual de usuario Pagina 59

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 138
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 58
Fibre to SAS/SATA II RAID Subsystem
User Manual
59
5.2.5 Activate Incomplete RAID Set
When Raid Set State is “Normal”, this means there is no failed disk drive.
When does a Raid Set State becomes “Incomplete”?
If the RAID subsystem is powered off and one disk drive is removed or has failed in
power off state, and when the subsystem is powered on, the Raid Set State will
change toIncomplete”.
The Volume Set(s) associated with the Raid Set will not be visible and the failed
or removed disk will be shown as “Missing”. At the same time, the subsystem
will not detect the Volume Set(s); hence the volume(s) is/are not accessible.